DC Cardioversion

Cardioversion is a procedure used to convert an irregular or abnormal heart rhythm to a normal heart rhythm by applying high energy shock. Common rhythms that may require elective cardioversion include atrial fibrillation, atrial flutter and ventricular tachycardia.

Open in seperate window click here

Click here to view DC Cardioversion Procedure Instructions

Back to Top

Cardiopulmonary exercise testing, often abbreviated as CPX, CPEX or CPET, is now the gold standard objective tool for the evaluation of cardiopulmonary function and fitness. It is an entirely non-invasive and objective method of assessing integrative exercise responsesinvolving the pulmonary, cardiovascular and skeletal musclesystems, which are not adequately reflected through the measurementof individual organ system function. Hence, CPX evaluates the way in which your heart, lungs and circulation simultaneously respond to exercise.

Open in seperate window click here

Back to Top

A pacemaker is a small electronic device that helps the heart to beat at a proper rate. It keeps track of your normal heartbeat, and can sense when it becomes too slow. When that happens, the pacemaker generates a small electrical impulse, very similar to the hearts natural impulse. This keeps your heart beating at a normal pace.

Your pacemaker has two main parts: the generator and the lead(s). The generator is a small, flat, lightweight metal case that contains a tiny computer and battery. This is the part that generates the electrical impulses. The leads are wires covered by soft, flexible plastic. Working together to regulate your heart, they monitor how well the heart is beating and will send electrical impulses from the generator to the heart when it senses it is necessary.

Open in seperate window click here

Clickhere to view Pacemaker Implantation Procedure Instructions

Back to Top

Ordinarily, your heart beats at a regular, steady pace called a normal sinus rhythm. It is regulated electrically by the sinus node. However, if certain cells in the lower chamber of your heart (the ventricles) begin to generate their own electrical impulses, these can override the hearts normal electrical control mechanism. These impulses do not follow the hearts normal conduction pathway, and may prevent the heart from pumping enough blood and oxygen through the body. One situation, called ventricular tachycardia (VT), may cause you to feel fluttering in the chest or throat or a sensation of dizziness and lightheadedness.

Because less blood is pumped with each beat, your body and brain receive less oxygen-carrying blood, which may result in dizziness, blackouts or fainting, and even unconsciousness. Sometimes VT can be prevented or treated with medications. In other cases, an electrical device is needed to deliver an impulse to the heart to stop the arrhythmia.

When the ventricular arrhythmia becomes even more rapid and unstable, it causes a condition called ventricular fibrillation (VF)-the heart is quivering, and no longer pumps any blood. This leads to cardiac arrest. The only way to correct ventricular fibrillation is to quickly deliver a strong electrical shock to the heart to stop the abnormal rhythm and prompt the hearts normal electrical conduction system to take over again. This process is called defibrillation.

In a hospital or ambulance, when emergencies cause life-threatening arrhythmias, defibrillation is done with an external device called a defibrillator. Paddles are placed against the chest, and a strong electrical impulse is delivered through the heart. However, if your arrhythmia (either ventricular tachycardia or fibrillation) occurs in routine situations, an automatic implantable cardioverter-defibrillator (ICD) can be implanted to monitor and deliver whatever therapy is necessary. It will be programmed to detect and diagnose either ventricular tachycardia or ventricular fibrillation, and will deliver the therapy necessary to correct your abnormal heart rhythms.

Your electrophysiologist may choose to implant a defibrillator in your body to monitor your heart rhythm around the clock and to immediately correct any dangerous arrhythmias should they occur.

The ICD has two components: the generator and the lead(s). The generator is a relatively small, flat, lightweight case that holds a tiny computer and battery. This will generate the electrical impulses used to regulate your heartbeat. The leads are wires covered with soft, flexible plastic. They are connected to the generator and tell it how the heart is beating. The leads also transmit the electrical impulses from the generator to the heart.

Open in seperate window click here

Click here to view Defibrillation Implantation Procedure Instructions

Back to Top

Our practice specializes in removing leads (pacemaker and/or defibrillator wires attached to the heart) by minimally invasive procedure called as laser lead extraction.

The procedure involves use of laser sheaths that breaks up the scar tissue built around leads. The procedure is minimally invasive and requires considerable operator expertise. Our practice does the highest number of laser lead extractions per year in the state of Arizona.

What happens during the procedure?

The procedure is performed in an operating room under general anesthesia. Once the patient is prepared for surgery, the physician makes an incision close to the old device, and the generator is removed. The most difficult part of this procedure is not removal of the device, but removal of the leads. The level of difficulty is typically related to the amount of scar tissue that has formed since the device was implanted. If the wires are unable to be removed with gentle pulling, a special laser extraction device is used. This device consists of a sheath wrapped in laser fiberoptics that is advanced through the targeted vein and over the lead. The physician applies a controlled dose of laser energy to break up (ablate) any scar tissue and free the lead that is then pulled out.

Every circumstance is different, so your doctor will let you know if a new pacemaker or defibrillator system will be implanted at that time or after a course of antibiotics. Patients can expect to be in surgery for approximately four hours and are usually admitted to stay one night in the hospital for monitoring and observation if no further treatment is required.

Why do leads need to be removed?

When a decision is made to implant a permanent pacemaker or implantable cardiac defibrillator (ICD), the expectation is that the device will remain in the patients body for the rest of his/her life. As with all medical devices, there are certain circumstances that require removal of the permanent system. Such circumstances include infection, inappropriate lead positioning, or lead failure which is often referred to as lead fracture or insulation breach. In addition, as cardiac pacing technology evolves, physicians may wish to upgrade a patients existing device with a newer more effective one.

The bodys natural response to a foreign object, such as a pacemaker is to form scar tissue surrounding the leads that course through blood vessels down into the heart. The longer the device remains inside the body, the more scar tissue will adhere to the leads, making removal difficult. Still, if the pacing device must be removed, leads cannot be abandoned, as they would interfere with new devices or cause damage to blood vessels.

There are a number of reasons that a physician might recommend extracting versus capping and leaving a lead in a lead in place:

The lead is not functioning properly. Sometimes the lead no longer provides a reliable connection between the pacemaker or ICD and the heart. This can be due to damage to the lead, called lead fracture. Large amounts of scar tissue forming at the tip of the lead may also cause the lead to need more energy to function than the pacemaker or ICD is able to deliver.

A pacemaker infection or ICD infection has developed. The device and leads may need to be removed to cure the infection.

The lead is interfering with blood flow to the heart. Leads that are not being used may need to be removed if they are blocking the flow of blood to the heart.

There may be a manufacturer advisory on the lead. If a lead has a higher risk of failure than normal, it may be under a manufacturer advisory and need to be removed for safety.

MRI inaccessibility. Newer pacemaker systems are designed to be safe in an MRI environment; however, older, non-compatible pacemaker leads may prohibit access to MRI diagnostic testing.

Is laser lead extraction safe?

The procedure is successful in 97.7% of patients,and multiple clinical studieshave demonstrated safety, effectiveness and efficiency of laser lead removal. The initial PLEXES trial (PLEXES Randomized Trial: Pacing Lead Extraction with the Excimer Laser Sheath) showed a significantly higher success rate in the removal of leads using the laser sheath over manual telescoping sheath tools alone: 94% vs. 64%, respectively.

The risk of internal bleeding, a tear in a vein or the heart, or death is very small; however, any medical procedure involves risks. Well-established professional recommendations and use instructions should be followed for every lead extraction procedure. Refer to Important Safety Information for Patients at the end of this media kit for complete information about risks.

What are the risks associated with this procedure?

Every medical procedure carries risk to your health, but in expert hands, laser lead extraction has about a 95 percent success rate, which is significantly higher than for the conventional procedure, known as percutaneous lead extraction.

Your doctor will discuss with you the risks and benefits of laser lead extraction. In general, this is a low risk procedure, but it does carry a one to two percent chance of life threatening complications. Common risks of this procedure include bleeding, bruising and infection where the incision is made. Less common risks include damage to the blood vessels, damage to the heart muscle, change in heart rhythm, heart attack, stroke, need for urgent cardiac surgery and death.

How does an excimer laser work?

Excimer laser is a cool laser similar to that used in LASIK for eye surgery. It produces pulsed bursts of UV light energy that are capable of gently dissolving fibrous tissue into tiny, microscopic particles that are easily absorbed by the bloodstream. This is also known as photoablation. This energy is transmitted along flexible glass fibers encased in catheters, which can be passed through arteries and veins. The UV light energy is then focused on the tissue that needs to be treated. The penetration depth is about 50 microns, or about the equivalent of the diameter of a human hair. The laser energy that is produced is absorbed by the binding tissue directly in front of the laser sheath tip, allowing a controlled removal of the lead.

What are the alternatives to laser lead removal?

Traction and non-laser sheaths are alternatives to laser lead removal. Traction is physically pulling on leads. The amount of traction required for lead extraction increases as the duration of the implant and the tensile strength of the fibrous overgrowth tissue increase. When fibrous tissue growth is substantial, traction alone is not sufficient. Other types of non-laser sheaths use different mechanisms to tear, cut or burn tissue away from the lead.

How long has laser lead removal been in use?

The pivotal randomized clinical trial demonstrating the safety and efficacy of the Spectranetics Laser Sheath (SLS) was completed in 1997. More than 15 years of clinical trials and publications continue to support the safety of the product.

Are there cases when the lead should not be removed?

When infection is present that does not involve the device or leads, when long-term antibiotics are required or when the patient has atypical lead placement, capping rather than removing the lead may be an appropriate solution based on physician evaluation.

There are important safety considerations to keep in mind, however: the risk of failed lead removal doubles every three years,and risk of infection increases 2% to 7% at each device change.Leaving non-functioning leads in place can also cause blood clots or blockages and prevent access for new leads.In some instances, there is lead on lead interaction that can cause electrical shocks or inappropriate pace/sense behavior in the device.

Recovery

After the procedure, patients may experience soreness, swelling and bruising at the site where the device and leads were removed. It takes approximately one week to physically recover from the surgery.

Open in seperate window click here

Click here to viewLaser Lead Extraction Procedure Instructions

Back to Top

Heart failure is a common and serious medical condition. Heart failure develops slowly over time as your heart muscle gradually weakens .The failure refers to your hearts inability to pump enough blood to meet your bodys needs. Congestive heart failure is a progressive condition in which the hearts function gradually deteriorates resulting in diminished cardiac performance and pumping ability. Ultimately, blood flow to the organs is reduced, leading to a variety of symptoms including shortness of breath, lack of energy, swelling, etc. Patients with heart failure often require repeated hospitalizations for treatment and adjustment of medications. Medications have been the mainstay of therapy for heart failure. However, patients with extreme forms of heart failure often remain highly symptomatic despite maximum medical therapy, and face grave risk.

Anywhere between one quarter to one half of all heart failure patients have delay in the electrical activation of the heart making the heart walls dys-synchronous and heart pump less efficient. This electrical abnormality, is often called bundle branch block or intraventricular conduction delay, on the electrocardiogram. If you have heart failure, your physician can readily tell you if you have this common abnormality. If present, electrical delay will adversely affect heart function resulting in inefficient pumping action of the heart. This electrical delay in the setting of heart failure is also associated with increase in the risk of death.

Recently, major advances have been made in technology that can overcome the problems created by the electrical abnormalities described above. Specifically, a therapeutic intervention termed cardiac resynchronization will reverse many or all of these abnormalities. Cardiac resynchronization is accomplished by a procedure called biventricular pacing. With this procedure, a standard two-wire pacemaker is placed in the right-sided cardiac chambers, and an additional wire is threaded through the vein of the heart to the left lower chambers freewall. By stimulating the right and left-sided chambers simultaneously, the heart walls are resynchronized. When this is accomplished, the vast majority of patients have improved cardiac function and reversal of the clinical consequences created by bundle branch block. The procedure can be successfully performed in 90-95% of patients with a risk of about 1%.

Clinical trials studying thousands of patients have been completed and published. They indicate significant improvement in overall heart failure outcome in patients treated with biventricular pacing devices. Patients report improvement of symptoms and exercise capacity. The hospitalization rates were also reduced.

Many patients with heart failure also face a risk of potentially fatal heart rhythms and sudden cardiac arrest. When this occurs, unless a patient is rapidly resuscitated, sudden death usually results. Standard treatment for a patient at high risk of sudden cardiac arrest is an implantable cardiac defibrillator. Biventricular pacing systems can be combined with the implantable defibrillator in appropriate patients to accomplish the dual desirable endpoints of improving heart failure and preventing sudden death.

Patients who have an unsuccessful implantation attempt of a biventricular pacing system due to unsuitable heart anatomy, may need placement of the third lead surgically directly on the heart surface. This is generally done by a Heart surgeon in the operation theater of a separate day. This lead is then tunneled and attached to the defibrillator/pacemaker.

Open in seperate window click here

Click here to viewCardiac Resynchronization Procedure Instructions

Back to Top

The S-ICD System is the worlds first and only subcutaneous implantable defibrillator that provides protection from sudden cardiac arrest (SCA) while leaving the heart and vasculature untouched. Like transvenous ICDs, the S-ICD System utilizes a pulse generator capable of delivering life-saving therapy. Unlike transvenous ICDs, the S-ICD System uses a subcutaneous electrode and analyzes the heart rhythm rather than individual beats to effectively sense, discriminate, and convert VT/VF. For years patients lives have been extended by implanting transvenous implantable defibrillators. Now the S-ICD System provides a new solution to protect patients from SCA, without touching the heart.

Effective Defibrillation Without Transvenous Leads

Sophisticated Technology

Durable Subcutaneous Electrode Design

New Solution for a Broad Range of Patients at Risk for SCA

Open in seperate window click here

Back to Top

Ordinarily, your heart beats at a regular, steady pace called a normal sinus rhythm that is regulated electrically by the sinus node. When the heart beats too rapidly, the arrhythmia is called a tachycardia. If the tachycardia originates in one of the upper chambers of the heart, its called a supraventricular (above the ventricles) tachycardia (SVT).

SVT may occur when an extra electrical pathway exists in or between some of the structures of the heart. These abnormal pathways can make the electrical impulses that control your heart rate travel in a circular pattern within the heart, causing a tachycardia. These arrhythmias can be treated, but not cured, with medications.

Your physician may choose to treat your arrhythmia with a non-surgical procedure called cardiac ablation. Often, this treatment permanently resolves the arrhythmia by destroying the abnormal pathway that causes it.

A cardiac ablation ablation is very similar to an Electrophysiology (EP) Study. If you havent already had an EP Study, the two procedures are frequently performed one after the other. The EP Study helps identify the specific type and location of the abnormal heart rhythm. Then, in a process called mapping, a catheter (small, flexible tube) is manipulated until it locates the abnormal pathway that is causing the tachycardia. At this point, an ablation is performed.

A special catheter will be used to direct energy to the abnormal pathway in the heart. Most commonly used energy is called Radiofrequency (RF). Radiofrequency energy is a form of electrical energy that causes the tissue at the tip of the catheter to heat up, permanently damaging (ablating) that small area of tissue. When the abnormal pathway is destroyed, the hearts electrical impulses can only travel through the normal conduction pathways, and the arrhythmia is eliminated.

Radiofrequency (RF) energy is radio waves that are converted to heat to ablate and create scar tissue. It reliably achieves transmurality and is the most widely used energy source in catheter ablations. In general, high temperatures are needed to make sure that all layers of tissue are ablated. Traditional catheters use unipolar radiofrequency energy, which simply means that the radiofrequency energy is transmitted from a single point at the catheters tip.

Cryo energy, is intense cold that is used to form ice crystals within the tissue, causing the cells to die and creating scar tissue. It may be easier to make lesions using cryothermy since the cold temperatures cause tissue to stick to the catheter. In addition, cryo energy may have fewer major complications. Animal studieshave shown cryo energy to have a much lower incidence of thrombus (clot) formation than radiofrequency energy, which suggests that cryothermy could lower the risk of a stroke. Cryo energy can be used in single point catheters or balloon catheters.

Laser energy is light waves that are converted to heat to ablate and create scar tissue. It may be a safer heat-based energy than unipolar radiofrequency energy. With laser energy, the catheter doesnt need to be in direct contact with tissue, which could mean it will have fewer complications than radiofrequency energy. Unlike other energy sources, contact force is not a factor in whether a laser lesion is transmural. In addition, laser energy can be adjusted when ablating tissues of varying thickness, with higher energy applied to thicker tissue and lower energy applied to thinner structures in the heart.

Other energy sources, such as microwave and high intensity focused ultrasound (HIFU), have been studied but these energy sources arent widely used in catheter ablation.

The design and functionality of catheters is constantly evolving. Most atrial fibrillation ablations today use single point radiofrequency energy catheters, which have a success ratefreedom from atrial fibrillationof about 70%. Its believed that different types of catheters could have higher success rates or fewer complications. Here are the different types of catheters available today for atrial fibrillation catheter ablations:

Single electrode radiofrequency catheters emit radiofrequency energy from a single point at the catheter tip. To make lesions, electrophysiologists ablate one spot after another, similar to drawing a line by making dots one after the other. If all the dots are not connected, afib could re-enter the heart in the unablated space (gap).

Multi-electrode radiofrequency catheters have several electrodes, each of which can deliver radiofrequency energy. These catheters can ablate a larger area of tissue than single point radiofrequency energy catheters, which could decrease procedure times. In addition, multielectrode catheters may be better at making contiguous lesions (lesion lines without any gaps) than single point catheters. Finally, these catheters can also deliver superficialbipolar radiofrequency energy, which may reduce injury to deeper tissues in certain areas of the heart. However, there is limited clinical data on multielectrode catheters, which means that complications arising from these procedures may not be fully known or understood.

These catheters require higher outputs, and are capable of forming larger lesions that the standard 4 mm tip catheters. Disadvantages of the 8 mm tip have included a decreased resolution of electrograms, greater catheter stiffness, and therefore decreased compliance and maneuverability.

Closed irrigation

Saline is perfused via a pump mechanism through the catheter tip, turns around within the catheter tip, and returns back to the pump. This represents a closed system because no saline is infused into the blood pool

Open Irrigation

Open irrigation overcomes the limitations of non-irrigated ablation by lowering electrode and tissue surface temperature, bringing together the efficacy of power delivery with the safety of reduced char formation.

Here is the original post:

Procedures - Arizona Heart Rhythm Center